Journal
ENERGY CONVERSION AND MANAGEMENT
Volume 44, Issue 11, Pages 1845-1851Publisher
PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/S0196-8904(02)00190-5
Keywords
cogeneration; electricity and steam; natural gas; ASPEN PLUS
Categories
Ask authors/readers for more resources
A detailed flow sheet of the combined cycle cogeneration plant fuelled by natural gas was prepared. The model for simulation of this plant was developed using the ASPEN PLUS software. The results generated using this model were compared with the operating data of the commercial plant generating about 43.6 MW of electricity by gas turbine and 28.6 MW of electricity by steam turbine. The electricity is supplied to the grid, whereas the low pressure steam is utilised locally for heating purposes. The key data generated using the ASPEN model are in good agreement with the operating data. Crown Copyright (C) 2002 Published by Elsevier Science Ltd. All rights reserved.
Authors