4.6 Article

Comparison of the Test-Retest Reliability of the Balance Computerized Adaptive Test and a Computerized Posturography Instrument in Patients With Stroke

Journal

ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION
Volume 95, Issue 8, Pages 1477-1483

Publisher

W B SAUNDERS CO-ELSEVIER INC
DOI: 10.1016/j.apmr.2014.03.005

Keywords

Postural balance; Psychometrics; Rehabilitation; Stroke

Funding

  1. Kaohsiung Municipal Ta-Tung Hospital in Taiwan [KMTTH-100-026]

Ask authors/readers for more resources

Objective: To compare the test-retest reliabilities of the scores of the Balance Computerized Adaptive Test (CAT) and the Biodex Balance System in patients with stroke. Design: A repeated-measures design (at a 1-wk interval) was used to examine the test-retest reliabilities of the scores of the Balance CAT and the Biodex Balance System. Setting: One rehabilitation unit in a local hospital. Participants: Patients (N=50) with stroke for more than 6 months and undergoing outpatient rehabilitation completed the Balance CAT and the eyes open (EO)/closed (EC) tests, but only 17 patients finished the Limit of Stability (LOS) test because they were unable to reach all the targets. Interventions: Not applicable. Main Outcome Measures: The Balance CAT and 2 computerized tests of the Biodex Balance System, namely the EO/EC test and the LOS, were used to evaluate balance function. Results: The test-retest reliabilities of the scores of the Balance CAT (Pearson r=.92, minimal detectable change [MDC] percent=12.8%) was excellent. Those of the EO/EC and LOS tests were poor to good (Pearson r=.56-.85, MDC%=50.8%-126.9%). Conclusions: The test-retest reliabilities of the scores of the Balance CAT were sufficient for assessing balance function in patients with stroke. Moreover, the test-retest reliabilities of the scores of the Balance CAT, one of the functional balance measures, were superior to those of the Biodex Balance System, 1 type of computerized posturography instrument. Therefore, the Balance CAT may be a more reliable measure for clinicians and researchers to use in assessing the balance function of patients with stroke for more than 6 months. (C) 2014 by the American Congress of Rehabilitation Medicine

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available