4.7 Article

Selective solid phase extraction and pre-concentration of heavy metals from seawater by physically and chemically immobilized 4-amino-3-hydroxy-2-(2-chlorobenzene)-azo-1-naphthalene sulfonic acid silica gel

Journal

MICROCHIMICA ACTA
Volume 143, Issue 1, Pages 65-70

Publisher

SPRINGER WIEN
DOI: 10.1007/s00604-003-0046-9

Keywords

selective extraction; pre-concentration; modified silica; heavy metals

Ask authors/readers for more resources

4-Amino-3-hydroxy-2-(2-chlorobenzene)azo-1-naphthalene sulfonic acid (AHCANSA) was used as a chelating modifier to improve the reactivity of the silica gel surface in terms of selective binding and extraction of heavy metal ions. The surface coverage values were found to be 0.488 and 0.473 mmol g(-1) for the newly modified physically adsorbed silica gel phase (I) and chemically immobilized-AHCANSA phase (II), respectively. The modified silica gel phases (I, II) were tested for stability in different acidic buffer solutions (pH 1-6) and found to be highly resistant to hydrolysis and leaching by buffer solutions above pH 2. The application of these two phases as solid extractors for a series of mono-, di-, and tri-valent metal ions from aqueous solutions was also performed with different controlling factors such as the pH value of metal ion solutions and equilibrium shaking time. The mmol g(-1) metal capacity values determined by silica gel phases (I, II) were found to confirm high affinity and selectivity characters for binding with heavy metal ions such as Cr3+, Ni2+, Cu2+, Zn2+, Cd2+ and Pb2+ in a range of 0.250-0.483. The tested alkali and alkaline earth metals, Na+, K+, Mg2+ and Ca2+, were found to exhibit little interaction and binding ability with the modified silica gel phases. The selectivity characters incorporated into the modified silica gel phases were further utilized and applied in solid phase extraction and pre-concentration of trace concentration levels (similar to1.0 mug mL(-1) and 2.00-2.50 ng mL(-1)) from real seawater samples. The 31 percentage recovery values determined for Cr3+, Cu2+, Zn2+, Cd2+ and Pb2+ were found to be in the range of 95.2-98.1 +/- 2.0-5.0%, and the pre-concentration recovery values for the same tested heavy metal ions were found to be in the range of 92.5-97.1 +/- 3.0-6.0% for the two newly modified silica gel phases with a pre-concentration factor of 500.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available