4.4 Article

Does cervical length and the lower placental edge thickness measurement correlates with clinical outcome in cases of complete placenta previa?

Journal

ARCHIVES OF GYNECOLOGY AND OBSTETRICS
Volume 284, Issue 4, Pages 867-873

Publisher

SPRINGER HEIDELBERG
DOI: 10.1007/s00404-010-1737-1

Keywords

Cervical length; Placental edge; Placenta previa; Preterm labor

Ask authors/readers for more resources

To evaluate the effectiveness of cervical length and the lower placental edge thickness measurement in predicting the risk of antepartum hemorrhage (APH) and emergency preterm cesarean delivery in women with complete placenta previa. Fifty-four cases with confirmed diagnosis of complete placenta previa in third-trimester were subjected to transvaginal sonographic measurement of cervical length and lower placental edge thickness and correlated this to clinical outcome with regards to gestational age at delivery, ante partum hemorrhage, emergency cesarean section before 36 weeks due to massive hemorrhage and neonatal birth weight. Antepartum bleeding and emergency cesarean section rate before 36 weeks due to massive bleeding were significantly higher in cases with thick lower placental edge or central placenta than cases with thin lower placental edge [16 cases (53.3%) vs. 5 cases (20.8%)] for the former and [14 cases (46.6%) vs. 4 cases (16.6%) for the later]. Antepartum bleeding was observed in 18 cases (51.4%) when cervical length measurements a parts per thousand currency sign30 mm of whom 16 cases (88.9%) had showed severe attack necessitated emergency cesarean delivery before 36 weeks versus 4 cases (21.1%) with cervical length a parts per thousand yen30 mm. By combining cervical length with lower placental edge thickness measurement sensitivity, specificity, positive predictive value (PPV) negative predictive value (NPV) and accuracy increased to 83.3, 78.4, 53.4, 79.8 and 89.7%, respectively for the prediction of antepartum bleeding and emergency cesarean section < 36 weeks using receiver-operating characteristics curve with area under the curve 0.882. Short cervical length at cut-off value a parts per thousand currency sign30 mm and increased lower placental edge thickness measurements may predict with high accuracy the risk of APH and emergency preterm cesarean delivery in patients with complete placenta previa.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.4
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available