4.5 Article

Functional cardiac MRI in preterm and term newborns

Journal

Publisher

B M J PUBLISHING GROUP
DOI: 10.1136/adc.2010.189142

Keywords

-

Categories

Funding

  1. Garfield Weston Foundation
  2. Medical Research Council
  3. Wellcome Trust
  4. Imperial College Comprehensive Biomedical Research Centre
  5. Dorothy Hodgkins Postgraduate Award
  6. Philips
  7. MRC [MC_U120081323, G0701896, MC_U120061309] Funding Source: UKRI
  8. British Heart Foundation [FS/11/75/29030] Funding Source: researchfish
  9. Medical Research Council [MC_U120061309, MC_U120081323, G0701896] Funding Source: researchfish

Ask authors/readers for more resources

Objective To use cardiac MRI techniques to assess ventricular function and systemic perfusion in preterm and term newborns, to compare techniques to echocardiographic methods, and to obtain initial reference data. Design Observational magnetic resonance and echocardiographic imaging study. Setting Neonatal Unit, Queen Charlotte's and Chelsea Hospital, London, UK. Patients 108 newborn infants with median birth weight 1627 (580-4140) g, gestation 32 (25-42) weeks. Results Mean (SD) flow volumes assessed by phase contrast (PC) imaging in 28 stable infants were left ventricular output (LVO) 222 (46), right ventricular output (RVO) 219 (47), superior vena cava (SVC) 95 (27) and descending aorta (DAo) 126 (32) ml/kg/min, with flow being higher at lower gestational age. Limits of agreement for repeated PC assessment of flow were LVO +/- 50.2, RVO +/- 55.5, SVC +/- 20.9 and DAo +/- 26.2 ml/kg/min. Mean (SD) LVO in 75 stable infants from three-dimensional models were 245 (47) ml/kg/min, with limits of agreement +/- 58.3 ml/kg/min. Limits of agreement for repeated echocardiographic assessment of LVO were +/- 108.9 ml/kg/min. Conclusions Detailed magnetic resonance assessments of cardiac function and systemic perfusion are feasible in newborn infants, and provide more complete data with greater reproducibility than existing echocardiographic methods. Functional cardiac MRI could prove to be a useful research technique to study small numbers of newborn infants in specialist centres; providing insights into the pathophysiology of circulatory failure; acting as an outcome measure in clinical trials of inotropic intervention and so guiding clinical practice in the wider neonatal community.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.5
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available