4.7 Article

Determination of nitrite using sensors based on nickel phthalocyanine polymer modified electrodes

Journal

TALANTA
Volume 62, Issue 2, Pages 351-355

Publisher

ELSEVIER SCIENCE BV
DOI: 10.1016/j.talanta.2003.08.003

Keywords

nitrite determination; modified electrode; tetraaminophthalocyanatonickle

Ask authors/readers for more resources

An amperometric nitrite sensor based on a polymeric nikel tetraaminothphalocyanine (p-NiTAPc) film coated glassy carbon (GC) electrode was developed. The mechanism of catalysis on the surface of the electrode was discussed. The sensor exhibited fast respond towards nitrite with a detection limit of 1 x 10(-7) M and a linear concentration range of 5 x 10(-7) to 8 X 10(-3) M. The possible interference from several common ions was tested. The proposed method was successfully applied in the detection of nitrite in real samples. (C) 2003 Elsevier B.V. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available