4.5 Article

Endovascular treatment of an iatrogenic thoracic aortic injury after spinal instrumentation: Case report

Journal

JOURNAL OF VASCULAR SURGERY
Volume 39, Issue 4, Pages 893-896

Publisher

MOSBY-ELSEVIER
DOI: 10.1016/j.jvs.2003.10.056

Keywords

-

Ask authors/readers for more resources

Iatrogenic aortic injuries after spinal surgery have been described, but are rare. We describe a case of a 77-year-old woman who underwent surgical correction of a debilitating spinal deformity at an outside institution. Postoperative thoracic spine radiographs and computed tomography scans revealed a misplaced pedicle screw at T5, which was impinging on the descending thoracic aortic wall. The patient was brought to the operating room, where a thoracic stent graft was deployed under fluoroscopic guidance as the malpositioned screw was manually retracted. The patient had an uneventful postoperative course, and was discharged within 24 hours. This case represents a rare but potentially morbid vascular complication of spinal instrumentation surgery that was successfully treated without the need for thoracotomy.