Journal
IEEE TRANSACTIONS ON POWER ELECTRONICS
Volume 19, Issue 3, Pages 862-868Publisher
IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
DOI: 10.1109/TPEL.2004.826520
Keywords
common-mode (CM); differential-mode (DM); EMI filter; switched mode power supply (SMPS)
Categories
Ask authors/readers for more resources
A novel approach to determine common-mode (CM) and differential-mode (DM) noise source impedances of a low-power switched mode power supply (SMPS) has been developed using a two current probes approach. The proposed approach allows measurement of noise source impedance of a SMPS without interrupting its normal operation. With proper setup calibration, the proposed approach can derive an equivalent circuit model, consisting of resistive and reactive components, to represent the noise source impedance with reasonable accuracy. Once the equivalent circuit model of the noise source impedance is obtained through the measurement, the most effective filter configuration and suitable component values for the built-in power line electromagnetic interference (EMI) filter of the SMPS could be designed with ease.
Authors
I am an author on this paper
Click your name to claim this paper and add it to your profile.
Reviews
Recommended
No Data Available