The uncertainty in contact angles from the Wilhelmy tensiometer was analyzed using standard error propagation techniques involving partial derivatives across the full range of wettability, from completely wetting to non-wetting surfaces. Uncertainties in force, sample perimeter, and liquid surface tension of 1% were shown to yield uncertainty in contact angles of a few degrees over the middle range of wettability, but exceeded 10 degrees at the extremes.