4.7 Article Proceedings Paper

Enzyme-linked immunosorbent assays based on rabbit polyclonal and rat monoclonal antibodies against isoproturon

Journal

JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY
Volume 52, Issue 9, Pages 2462-2471

Publisher

AMER CHEMICAL SOC
DOI: 10.1021/jf035498d

Keywords

rabbit polyclonal antiserum; rat monoclonal antibodies; isoproturon; 4-isopropylanilin; 4-isopropylphenylurea; 1-(4-isopropylphenyl)-3-methylurea; urea herbicides; immunoassay; ELISA; water

Ask authors/readers for more resources

This work describes the production and characterization of rabbit polyclonal antisera (pAb) and rat monoclonal antibodies (mAb) against isoproturon. Coating antigen and enzyme-tracer formats were developed. Standard curves for isoproturon were conducted either in 40 mM phosphate buffered saline (PBS) or in Milli-Q water. PAb 352 together with the best enzyme tracer revealed in the optimized ELISA (enzyme tracer format) a test midpoint of 1.06 +/- 0.34 mug/L (n = 19, standard set up in Milli-Q water) with a detection limit of about 0.1 mug/L. The comparable ELISA with mAb IOC 7E1 had test midpoints of 0.07 +/- 0.04 mug/L (n = 7, standards in Milli-Q water) and 0.11 +/- 0.08 mug/L (n = 33; standards in 40 mM IPBS). The limits of detection were about 0.003 and 0.01 mug/L in Milli-Q water and PBS, respectively. Noticeable cross reactivities (CRs) were seen with the major metabolites, namely 4-isopropylaniline, 4-isopropylphenylurea, and 1-(4-isopropylphenyl)-3-methylurea. With pAb 352, these CRs were 5%, 7%, and 31%, respectively, and with mAb IOC 7E1, they were 3%, 5%, and ca. 19%, respectively. All arylurea herbicides had only minor CRs, which ranged from no CR (e.g., chlorosulfuron) to a maximum of 3.3% (chlortoluron). Influences of organic solvents (methanol, ethanol, acetonitrile, and acetone) were evaluated. Both pAb- and mAb-based immunoassays showed the highest tolerance for methanol, up to 5%. Ethanol and acetonitrile could not be used above 2% without an influence on the assays. The same was true for acetone, although tested only in the mAb-based assay. Water samples of different origins and matrices were spiked and analyzed with these pAb and mAb ELISAs. The results demonstrated that these immunoassays are useful screening tools.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available