4.7 Article

High temperature corrosion of coatings and boiler steels below chlorine-containing salt deposits

Journal

CORROSION SCIENCE
Volume 46, Issue 6, Pages 1311-1331

Publisher

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.corsci.2003.09.026

Keywords

high temperature corrosion; metal coatings; steel; molten salts

Ask authors/readers for more resources

High temperature corrosion tests were performed on low-alloy ferritic steel and austenitic stainless steel, five high velocity oxy-fuel (HVOF) coatings, a laser cladding, and a diffusion chromized steel. Test conditions simulated Superheater conditions of biofuel-fired boiler. The samples were exposed to synthetic salt containing 40 wt% K2SO4, 40 wt% Na2SO4, 10 wt% KCl, and 10 wt% NaCl. Exposures were carried Out in oxidizing and in reducing atmospheres. The test temperature was 550 degreesC and the test duration was 100 h. Corrosion was extremely severe in oxidizing conditions because of active oxidation. In reducing atmosphere corrosion was retarded due to depletion of chlorine in the scales by evaporation of metal chlorides, and formation of a layer rich in chromium, sodium, sulfur, and oxygen adjacent to the metal surface. The corrosion resistance of coatings was determined by composition and microstructure. Oxides at splat boundaries were attacked by chlorine, and chlorine was able to penetrate through the coatings along splat boundaries. (C) 2003 Elsevier Ltd. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available