4.7 Article Proceedings Paper

Chemiluminescence sensor for local equivalence ratio of reacting mixtures of fuel and air (FLAMESEEK)

Journal

APPLIED THERMAL ENGINEERING
Volume 24, Issue 11-12, Pages 1619-1632

Publisher

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.applthermaleng.2003.10.028

Keywords

premixed combustion; chemiluminescence sensor; OH*; CH* and C-2* excited radicals; OHPLIF; humidified flame

Ask authors/readers for more resources

This paper describes a Cassegrain optics-based chemiluminescence sensor (CS) for measurements in gas turbine combustors. The chemiluminescence sensor measures the equivalence ratio of reacting fuel and air mixtures, and can identify the flame location, in partially premixed flames. It has the potential for monitoring the degree of premixedness of reacting fuel and air in industrial gas turbine combustors, where operation with lean premixed mixtures is important for reduction of NO, emissions. The spatial resolution of the sensor is evaluated by comparing OH* chemiluminescence measurement from the CS with laser induced OH fluorescence, in the cone-shaped premixed flame of a Bunsen burner. The ability of the sensor to measure in a modified micro-gas turbine environment burning a methane/air, as well as, a methane/ water/air flame (humidified flame) is also demonstrated. (C) European Communities, 2004. Published by Elsevier Ltd. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available