4.7 Article

Long-term assessment of a novel biodegradable paclitaxel-eluting coronary polylactide stent

Journal

EUROPEAN HEART JOURNAL
Volume 25, Issue 15, Pages 1330-1340

Publisher

OXFORD UNIV PRESS
DOI: 10.1016/j.ehj.2004.06.010

Keywords

stents; polymer; restenosis; paclitaxel

Ask authors/readers for more resources

Aim The aim of this study was to assess technical feasibility, biocompatibility, and impact on coronary stenosis of a new biodegradable paclitaxel-loaded polylactide stent. Due to high rates of in-stent restenosis and permanent nature of metal stent implants, synthetic polymers have been proposed as surrogate materials for stents and local delivery systems for drugs. Paclitaxel was shown to inhibit vascular smooth muscle cell proliferation and migration. Methods and results A novel biodegradable double-helical stent was manufactured using controlled expansion of saturated polymers (CESP) for the moulding of a bioresorbable poly(D, L)-lactic acid (PDLLA). A modified balloon catheter for stent deployment was developed according to the mechanical stent properties. Twelve paclitaxel-loaded (170 mug) polylactide stents, 12 unloaded polylactide stents, and 12 +/- 316L bare metal stents were deployed in porcine coronary arteries of 36 animals. Six pigs of each group were sacrificed after 3 weeks and 3 months, respectively, for every setting. Drug release kinetics as well as histomorphometrical and histopathological analyses were performed. A slow paclitaxel release kinetic for more than 2 months and therapeutic tissue concentrations were demonstrated. Coronary stenosis after implantation of paclitaxel-loaded stents (30 +/- 5% or 49 +/- 4%) was significantly inhibited compared to unloaded PDLLA stents (65 +/- 10%, P = 0.021 or 71 +/- 4%, P = 0.004) and metal stents (53 +/- 6% or 68 +/- 8%, P = 0.029 and P = 0.020) after 3 weeks or 3 months. Early complete endothelialisation was shown. Nevertheless, a local inflammatory response to the polylactide as a result of the polymer resorption process was observed. Conclusions This novel polylactide stent showed sufficient mechanic stability, and by incorporation of paclitaxel, a significant potential to reduce restenosis development after vascular intervention was seen. (C) 2004 Published by Elsevier Ltd on behalf of The European Society of Cardiology.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available