4.7 Article Proceedings Paper

Quality specifications for biochemical markers of myocardial injury

Journal

CLINICA CHIMICA ACTA
Volume 346, Issue 1, Pages 65-72

Publisher

ELSEVIER
DOI: 10.1016/j.cccn.2004.02.035

Keywords

troponin I; troponin T; acute coronary syndrome; heterophilic antibodies; macrocomplex

Ask authors/readers for more resources

Background: The current approach to the diagnosis and monitoring of myocardial damage, recognizes to biochemical markers, and in particular to troponins, a key role being well demonstrated that all elevated values were associated with a worsened prognosis. In 2001, the IFCC Committee on Standardization of Markers of Cardiac Damage published guidelines addressing the quality specifications for troponin assays in order to guarantee an analytical performance satisfying medical requirements and to standardize the quality of commercial methods. We describe how the application of quality specifications may be useful in daily practice, in order to provide advice to clinicians in the investigations of complex clinical cases of patients suffering from myocardial damage. Materials and methods: The samples from three patients (cases 1-3) admitted to the hospital with symptoms suggestive of cardiac disease, showing high troponin I (cTnI) values not correlated with clinical condition, were investigated in order to verify the accuracy of the laboratory data. The standard of quality specifications related to assay specificity, imprecision and interferences were evaluated using different platforms for cTnI assays, carrying out imprecision profile and specific studies on more common interferents in immunoassays. Results: The obtained results allow us to demonstrate two cases of false-positive cTnI values attributable to a macrocomplex between a modified in vivo cTnI and immunoglobulin G (case 1) and to a presence of heterophilic antibodies affecting the RxL Dimension procedure (case 3). Instead, the accuracy of data obtained in case 2 was evidenced by the imprecision profile obtained in our laboratory and by the comparison of results between different laboratories using same platform. Conclusions: The lack of standardization as well as the wide differences in the development of each assay give rise to major concerns regarding cTnI determinations. The laboratory must therefore check the compliance between the analytical characteristics of the method utilised against recommended quality specifications for a reliable understanding of the frequency of false-positive results as well as other serious analytical errors. (C) 2004 Elsevier B.V. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available