4.5 Article

Loaded custom-made zirconia and titanium implants show similar osseointegration:: An animal experiment

Journal

JOURNAL OF PERIODONTOLOGY
Volume 75, Issue 9, Pages 1262-1268

Publisher

AMER ACAD PERIODONTOLOGY
DOI: 10.1902/jop.2004.75.9.1262

Keywords

comparison studies; dental implants; dental instruments; dental plaque/prevention and control; scaling/instrumentation; ultrasonic therapy/instrumentation

Ask authors/readers for more resources

Background: Zirconia might be an alternative material to titanium for dental implant fabrication. The aim of the present study was to investigate the histological behavior (osseointegration) of loaded zirconia implants in an animal model and to compare it with the behavior of titanium implants. Methods: Five months after extraction of the upper anterior teeth, 12 custom-made titanium implants (control group) and 12 custom-made zirconia implants (test group) were inserted in the extraction sites in six monkeys. Before insertion, the titanium implant surfaces were sandblasted with Al2O3 and subsequently acid-etched. The zirconia implants were only sandblasted. Six months following implant insertion, impressions were taken for the fabrication of single crowns. A further 3 months later, non-precious metal crowns were inserted. Five months after insertion of the crowns, the implants with the surrounding hard and soft tissues were harvested, histologically prepared, and evaluated under the light microscope regarding the peri-implant soft tissue dimensions and mineralized bone-to-implant contact. Results: No implant was lost during the investigational period. The mean height of the soft peri-implant tissue cuff was 5 mm around the titanium implants and 4.5 mm around the zirconia implants. No statistically significant differences were found in the extent of the different soft tissue compartments. The mean mineralized bone-to-implant contact after 9 months of healing and 5 months of loading amounted to 72.9% (SD: 14%) for the titanium implants and to 67.4% (SD: 17%) for the zirconia implants. There was no statistically significant difference between the different implant materials. Conclusion: Within the limits of this animal experiment, it can be concluded that the custom-made zirconia implants osseointegrated to the same extent as custom-made titanium control implants and show the same peri-implant soft tissue dimensions.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.5
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available