4.6 Article

Effects of mechanical uncouplers, diacetyl monoxime, and cytochalasin-D on the electrophysiology of perfused mouse hearts

Journal

Publisher

AMER PHYSIOLOGICAL SOC
DOI: 10.1152/ajpheart.00234.2004

Keywords

optical action potentials; action potentials; intracellular calcium; restitution kinetics

Funding

  1. NHLBI NIH HHS [HL 59614, HL 70250, HL 69067, HL 57929] Funding Source: Medline

Ask authors/readers for more resources

Chemical uncouplers diacetyl monoxime ( DAM) and cytochalasin D (cyto-D) are used to abolish cardiac contractions in optical studies, yet alter intracellular Ca2+ concentration ([Ca2+](i)) handling and vulnerability to arrhythmias in a species-dependent manner. The effects of uncouplers were investigated in perfused mouse hearts labeled with rhod-2/AM or 4-[beta-[2(di-n-butylamino)-6-naphthyl]vinyl]pyridinium (di-4-ANEPPS) to map [Ca2+](i) transients (emission wavelength = 585 +/- 20 nm) and action potentials (APs) (emission wavelength > 610 nm; excitation wavelength = 530 +/- 20 nm). Confocal images showed that rhod-2 is primarily in the cytosol. DAM (15 mM) and cyto-D (5 muM) increased AP durations (APD(75) = 20.0 +/- 3 to 46.6 +/- 5 ms and 39.9 +/- 8 ms, respectively, n = 4) and refractory periods (45.14 +/- 12.1 to 82.5 +/- 3.5 ms and 78 +/- 4.24 ms, respectively). Cyto-D reduced conduction velocity by 20% within 5 min and DAM by 10% gradually in 1 h (n = 5 each). Uncouplers did not alter the direction and gradient of repolarization, which progressed from apex to base in 15 +/- 3 ms. Peak systolic [Ca2+](i) increased with cyto-D from 743 +/- 47 (n = 8) to 944 +/- 17 nM (n = 3, P = 0.01) but decreased with DAM to 398 +/- 44 nM (n = 3, P = 0.01). Diastolic [Ca2+](i) was higher with cyto-D (544 +/- 80 nM, n = 3) and lower with DAM (224 +/- 31, n = 3) compared with controls (257 +/- 30 nM, n = 3). DAM prolonged [Ca2+](i) transients at 75% recovery (54.3 +/- 5 to 83.6 +/- 1.9 ms), whereas cyto-D had no effect (58.6 +/- 1.2 ms; n = 3). Burst pacing routinely elicited long-lasting ventricular tachycardia but not fibrillation. Uncouplers flattened the slope of AP restitution kinetic curves and blocked ventricular tachycardia induced by burst pacing.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available