4.6 Article

Gas loading of graphene-quartz surface acoustic wave devices

Journal

APPLIED PHYSICS LETTERS
Volume 103, Issue 6, Pages -

Publisher

AMER INST PHYSICS
DOI: 10.1063/1.4818465

Keywords

-

Funding

  1. Royal Society [RG100570]

Ask authors/readers for more resources

Graphene was transferred to the propagation path of quartz surface acoustic wave devices and the attenuation due to gas loading of air and argon measured at 70 MHz and 210 MHz and compared to devices with no graphene. Under argon loading, there was no significant difference between the graphene and non-graphene device and the values of measured attenuation agree well with those calculated theoretically. Under air loading, at 210 MHz, there was a significant difference between the non-graphene and graphene devices, with the average value of attenuation obtained with the graphene devices being approximately twice that obtained from the bare quartz devices. (C) 2013 AIP Publishing LLC.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available