4.2 Article

Simultaneous determination of steroid composition of human testicular fluid using liquid chromatography tandem mass spectrometry

Journal

STEROIDS
Volume 69, Issue 11-12, Pages 721-726

Publisher

ELSEVIER SCIENCE INC
DOI: 10.1016/j.steroids.2004.05.020

Keywords

testes; testosterone; dihydrotestosterone; estradiol; mass spectrometry

Ask authors/readers for more resources

A rapid, sensitive, and specific method using liquid chromatography tandem mass spectrometry (LC/MS/MS) has been developed for simultaneous determination of testosterone (T), dihydrotestosterone (DHT), estradiol (E2), and 5alpha-androstan-3alpha, -17beta-diol (3alpha-Diol) within human testicular fluid. Sample pretreatment involved a one-step extraction with diethyl ether. The analytes were separated on a Waters X-Terra(TM) C-18 (150 mm x 2.1 mm i.d., 3.5 mum) analytical column with acetonitrile/water mobile phase (70:30, v/v) containing 0.1% formic acid using isocratic flow at 0.15 ml/min for 8 min. The column effluent was monitored by tandem mass spectrometry with electrospray positive ionization. Linear calibration curves were generated over the range of 0.1-50 ng/ml for T, 0.02-1 ng/ml for DHT, 0.05-2 ng/ml for E2, and 0.2-10 ng/ml for 3alpha-Diol, with values for the coefficient of determination of >0.99. The overall extraction efficiency was greater than 86% for T, 75% for DHT, 66% for E2, and 60% for 3alpha-Diol. The values for within-day and between-day precision and accuracy were <15%. We measured each of the four steroids in testicular sample volumes of only 20 mul, obtained by percutaneous testicular aspiration. The mean intratesticular testosterone concentration found by LC/MS/MS, 572 +/- 102 ng/ml, was similar to that previously obtained by radioimmunoassay (RIA). The mean intratesticular estradiol concentration was 15.7 +/- 12.3 ng/ml, which also correlated well with RIA measurement. Both DHT and 3alpha-Diol were below the limits of detection by RIA, but could be measured accurately by LC/MS/MS. In conclusion, LC/MS/MS represents a sensitive and accurate means by which to measure four separate steroids within small volume samples of testicular fluid. (C) 2004 Elsevier Inc. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.2
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available