4.4 Article

Correlation analysis between anticonvulsant ED50 values of antiepileptic drugs in mice and rats and their therapeutic doses and plasma levels

Journal

EPILEPSY & BEHAVIOR
Volume 5, Issue 6, Pages 866-872

Publisher

ACADEMIC PRESS INC ELSEVIER SCIENCE
DOI: 10.1016/j.yebeh.2004.08.021

Keywords

antiepileptic drugs; average steady-state concentration; therapeutic daily dose; anticonvulsant animal model

Ask authors/readers for more resources

Objective. Although there are several animal models of epilepsy, the extrapolation of antiepileptic drug (AEDs) performance to epileptic patients from anticonvulsant activity results in animals is not straightforward. Consequently, the aim of this work was to perform a correlation analysis between therapeutic daily doses (D) and average steady-state plasma concentrations (Cs-s,Cs-av) of AEDs and their activity in common anticonvulsant animal models. Methods. AED activity in anticonvulsant animal models was expressed as maximal electroshock seizure (MES) test ED50 values in mice and rats and ED50 values in audiogenic seizure-susceptible mice (AGS ED50). Data were examined, by use of linear and logarithmic approaches, for an association between C-ss,C-av (trig/L or mumol/L) and D (mg or mmol) for each AED in epileptic patients as the dependent variable ()) and its MES ED50 in mice and rats and AGS ED50 in mice (mg/kg or mumol/kg) as the independent variable (A. Results. Linear correlation analyses between C-ss,C-av (mg/L) and ED50 (mg/kg) for 11 AEDs gave the following correlation coefficients (R-2): 0.68 (mice, MES); 0.73 (rat, MES); 0.64 (AGS). Switching the units from milligrams to micromoles improved the correlation significantly and gave the following R-2 values: 0.88 (mice, MES); 0.90 (rat, MES); 0.76 (AGS). The linear correlation between C-ss,C-av and ED50 was better than that between D and ED50. Conclusions. The results of this analysis suggest that the relationship between C-ss,C-av and ED50 is useful in predicting target concentration ranges in humans. The Y intercepts of the C-ss,C-av-versus-ED50 and D-versus-ED50 plots were similar in all three animal models and ranged between 12 and 17 mg/L and between 570 and 890 mg, respectively, indicating that for all AEDs analyzed except valproic acid and ethosuximide, the therapeutic plasma concentration is in the range 10-20 mg/L. (C) 2004 Elsevier Inc. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.4
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available