4.5 Article

Vertical focusing device utilizing dielectrophoretic force and its application on microflow cytometer

Journal

JOURNAL OF MICROELECTROMECHANICAL SYSTEMS
Volume 13, Issue 6, Pages 923-932

Publisher

IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
DOI: 10.1109/JMEMS.2004.838352

Keywords

dielectrophoretic force; flow cytometer; hydrodynamic force; microelectromechanical systems (MEMS); three-dimensional (3-D) focusing

Ask authors/readers for more resources

Focusing of particles/cells in the vertical direction inside a micromachined flow cytometer is a critical issue while using an embedded optical detection system aligned with microchannels. Even if the particles/cells have been focused centrally in the horizontal direction using coplanar sheath flows, appreciable errors may still arise if they are randomly distributed in the vertical direction. This paper presents a vertical focusing device utilizing dielectrophoretic (DEP) forces and its application on micromachined flow cytometer. A pair of parallel microelectrodes is deposited on the upper and bottom surface of the microfluidic channel to drive particles/cells into the vertical center of the sample flow. This new microfluidic device is capable of three-dimensional (3-D) focusing of microparticles/cells and thus improves the uniformity of the optical detection signals. This 3-D focusing feature of the sample now is realized utilizing the combination of dielectrophoretic and hydrodynamic forces. Initially, two sheath flows are used to focus the sample flow horizontally by means of hydrodynamic forces, and then two embedded planar electrodes apply negative DEP forces to focus the particles/cells vertically. A new micromachined flow cytometer integrated with an embedded optical detection mechanism is then demonstrated. Numerical simulation is used to analyze the operation conditions and the dimension of the microelectrodes for DEP manipulation. The dynamic trace of the moving particles/cells within a flow stream under the DEP manipulation is calculated numerically. Micro polystyrene beads and diluted human red blood cells (RBC) are used to test the performance of the propose device. The experimental results confirm the suitability of the proposed device for applications requiring precise counting of particles or cells. Experimental data indicate the proposed method can provide more stable signals over the other types of micromachined flow cytometers that were previously reported.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.5
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available