4.5 Article

Reduction of Threshold Current for Domain Wall Depinning Using Gd Doping of Permalloy

Journal

APPLIED PHYSICS EXPRESS
Volume 3, Issue 8, Pages -

Publisher

JAPAN SOC APPLIED PHYSICS
DOI: 10.1143/APEX.3.083002

Keywords

-

Funding

  1. European Science Foundation
  2. Engineering and Physical Sciences Research Council
  3. Spanish Ministry of Science and Innovation [2008-0352]
  4. EPSRC [EP/G005176/1] Funding Source: UKRI
  5. Engineering and Physical Sciences Research Council [EP/G005176/1] Funding Source: researchfish

Ask authors/readers for more resources

The dependence of threshold current on applied magnetic field for domain wall depinning from a pinning potential in Gd doped permalloy wires is measured using pulsed current measurements By increasing the Gd concentration we find a marked reduction in threshold currents This is shown to arise due to the enhanced non-adiabatic spin-transfer torque we calculate the non-adiabaticity parameter beta to be around 0 11 for 10% Gd concentration On the other hand we show that the adiabatic spin-transfer torque is largely unaffected by Gd concentrations up to 10% (C) 2010 The Japan Society of Applied Physics