Delivery of systemic chemotherapeutic agent to tumors by using focused ultrasound: Study in a murine model

Journal

RADIOLOGY
Volume 234, Issue 2, Pages 431-437

Publisher

RADIOLOGICAL SOC NORTH AMERICA
DOI: 10.1148/radiol.2342030889

Keywords

-

Ask authors/readers for more resources

PURPOSE: To quantitatively determine the delivery of systemic liposomal doxorubicin to tumors treated with pulsed high-intensity focused ultrasound and to study the mechanism underlying this delivery in a murine model. MATERIALS AND METHODS: All animal work was performed in compliance with guidelines and approval of institutional animal care committee. C3H mice received subcutaneous injections in the flank of a-cell suspension of SCC7, a murine squamous cell carcinoma cell line; mice (n = 32) in drug delivery study received unilateral injections, whereas mice (n = 10) in mechanistic study received bilateral injections. Tumors were treated when they reached 1 cm(3) in volume. In the drug delivery study, doxorubicin hydrochloride liposomes were injected into the tail vein: Mice received therapy with doxorubicin injections and high-intensity focused ultrasound, doxorubicin injections alone, or neither form of therapy (controls). Tumors were removed, and the,doxorubicin content was assayed with fluorescent spectrophotometry. In the mechanistic study, all mice received an injection of 500-kDa dextran-fluorescein isothyocyanate into the tail vein, and half of them were exposed to high-intensity focused ultrasound prior to injection. Contralateral tumors served as controls for each group. Extravasation of dextranfluorescein isothyocyanate was observed by using in vivo confocal microscopy. RESULTS: Mean doxorubicin concentration in tumors treated with pulsed high-intensity focused ultrasound was 9.4 mug . g(-1) +/- 2.1 (standard deviation), and it was significantly higher (124% [9.4 mug . g(-1)/4.2 mug . g(-1)]) than in those that were not treated with high-intensity focused ultrasound (4.2 mug . g(-1) +/- 0.95) (P <.001, unpaired two-tailed Student t test). Extravasation of dextran-fluorescein isothyocyanate was observed in the vasculature of tumors treated with high-intensity focused ultrasound but not in that of untreated tumors. CONCLUSION: Pulsed high-intensity focused ultrasound is an effective method of targeting systemic drug delivery to tumor tissue. Potential mechanisms for producing the observed enhancement are discussed.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available