Journal
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT
Volume 538, Issue 1-3, Pages 358-371Publisher
ELSEVIER SCIENCE BV
DOI: 10.1016/j.nima.2004.09.009
Keywords
scintillation counter; photoelectron; amplifier; optical; magnetic field; CDF; photomultiplier
Ask authors/readers for more resources
New scintillation counters have been designed and constructed for the upgradation of the CDF detector at the Fermilab Tevatron in order to complete the muon coverage of the central detector and to extend it to a larger pseudorapidity interval. A novel light collection technique using wavelength shifting fibers, together with high-quality polystyrene-based scintillator resulted in compact counters with good and stable light collection efficiency over lengths extending up to 320 cm. Their design and construction is described and results of their initial performance are reported. (C) 2004 Elsevier B.V. All rights reserved.