4.6 Article

Uniformly sized molecularly imprinted polymer for atropine and its application to the determination of atropine and scopolamine in pharmaceutical preparations containing scopolia extract

Journal

JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS
Volume 37, Issue 2, Pages 231-237

Publisher

ELSEVIER
DOI: 10.1016/j.jpba.2004.10.017

Keywords

molecularly imprinted polymer; atropine; scopolamine; scopolia extract; column switching; pharmaceutical analysis

Ask authors/readers for more resources

A uniformly sized molecularly imprinted polymer (MIP) for atropine has been prepared. The MIP was prepared using 2-(trifluoromethyl) acrylic acid and ethylene glycol dimethacrylate as a functional monomer and cross-linker, respectively, by a multi-step swelling and thermal polymerization method. The selectivity factor, which is defined as the ratio of the retention factors (k) on the molecularly imprinted and non-imprinted polymers, k(imprinted)/k(non-imprinted), was 2.2 for atropine on the MIP. The obtained MIP was applied for the determination of tropane alkaloids (atropine and scopolamine) in a commercial gastrointestinal drug by a column-switching HPLC system, consisting of all MIP material as a pre-column. and a conventional cation-exchange analytical column. An interference peak was observed at the retention time of atropine derived from pre-column. However, since the peak area was less than 0.5% the peak area of atropine of a standard solution under the analytical conditions of this study (0.2 mug of atropine was loaded), this interference was negligible in the determination of atropine. On the other hand, no interference peak was observed at the retention time of scopolamine. Calibration curves of atropine and scopolamine showed food linearity in the range of 0.02-0.9 mug/ml (r = 0.9999) and 0.003-0.09 mug/ml (r = 0.9998), respectively. The mean recoveries of atropine and scopolamine from a placebo pharmaceutical preparation sample were 98.9 and 99.9%, respectively. The intra-day precision (measured by relative standard deviation, R.S.D. (%)) of both ingredients was less than 2.0%. The optimized column-switching system was applied successfully to the determination of atropine and scopolamine in a commercial gastrointestinal drug. (C) 2004 Elsevier B.V. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available