4.6 Article

Thrombus Formation Following Transcatheter Aortic Valve Replacement

Journal

JACC-CARDIOVASCULAR INTERVENTIONS
Volume 8, Issue 5, Pages 728-739

Publisher

ELSEVIER SCIENCE INC
DOI: 10.1016/j.jcin.2015.03.005

Keywords

antiplatelet therapy; thrombosis; transcatheter aortic valve replacement; valve-in-valve

Funding

  1. Medtronic, Inc.
  2. Abbott Vascular
  3. BioSensors International
  4. Biotronik
  5. Boston Scientific
  6. Medtronic
  7. MicroPort Medical
  8. OrbusNeich Medical
  9. SINO Medical Technology
  10. Terumo Corporation

Ask authors/readers for more resources

OBJECTIVES This paper reviews the published data and reports 3 cases of thrombosis involving CoreValve (Medtronic, Minneapolis, Minnesota) and 1 involving Edward Sapien (Edwards Lifesciences, Irvine, California) devices. Three of these cases had pathological findings at autopsy. BACKGROUND Only a limited number of cases of valve dysfunction with rapid increase of transvalvular aortic gradients or aortic insufficiency post-transcatheter aortic valve replacement (TAVR) have been described. This nonstructural valvular dysfunction has been presumed to be because of early pannus formation or thrombosis. METHODS Through reviews of the published reports and 4 clinical cases, pathological and clinical findings of early valve thrombosis are examined to elucidate methods for recognition and identifying potential causes and treatments. RESULTS This paper presents 4 cases, 2 of which had increasing gradients post-TAVR. All 3 pathology cases showed presence of a valve thrombosis in at least 2 TAV leaflets on autopsy, but were not visualized by transthoracic echocardiogram or transesophageal echocardiogram. One case was medically treated with oral anti coagulation with normalization of gradients. The consequence of valve thrombosis in all 3 pathology patients either directly or indirectly played a role in their early demise. At least 18 case reports of early valve thrombosis have been published. In 12 of these cases, the early treatment with anticoagulation therapy resolved the thrombus formation and normalized aortic pressures gradients successfully. CONCLUSIONS These 4 cases elucidate the occurrence of valve thrombosis post-TAVR. Consideration should be given to treatment with dual antiplatelet therapy and oral anticoagulation in patients post-TAVR with increasing mean pressure gradients and maximum aortic valve velocity. Further research should be conducted to create guidelines for antithrombotic therapy following TAVR procedure. (C) 2015 by the American College of Cardiology Foundation.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available