4.6 Letter

Motion artifact cancellation in NIR spectroscopy using Wiener filtering

Journal

IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING
Volume 52, Issue 5, Pages 934-938

Publisher

IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
DOI: 10.1109/TBME.2005.845243

Keywords

motion artifact cancellation; NIR spectroscopy; Wiener filtering

Ask authors/readers for more resources

We present a Wiener filtering based algorithm for the elimination of motion artifacts present in Near Infrared (NIR) spectroscopy measurements. Until now, adaptive filtering was the only technique used in the noise cancellation in NIR studies. The results in this preliminary study revealed that the proposed method gives better estimates than the classical adaptive filtering approach without the need for additional sensor measurements. Moreover, this novel technique has the potential to filter out motion artifacts in functional near infrared (fNIR) signals, too.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available