Recommendations of the American Association of Physicists in Medicine regarding the impact of implementing the 2004 task group 43 report on dose specification for 103Pd and 125I interstitial brachytherapy

Journal

MEDICAL PHYSICS
Volume 32, Issue 5, Pages 1424-1439

Publisher

WILEY
DOI: 10.1118/1.1884925

Keywords

Pd-103; I-125; permanent interstitial brachytherapy; air-kerma strength; dose prescriptions

Ask authors/readers for more resources

In March 2004, the recommendations of the American Association of Physicists in Medicine (AAPM) on the interstitial brachytherapy dosimetry using 125 1 and Pd-103 were reported in Medical Physics [TG-43 Update: Rivard et al., 31, 633-674 (2004)]. These recommendations include some minor changes in the dose-calculation formalism and a major update of the dosimetry parameters for eight widely, used interstitial brachytherapy sources. A full implementation of these recommendations could result in unintended changes in delivered dose without corresponding revisions in the prescribed dose. Because most published clinical experience with permanent brachytherapy is based upon two widely used source models, the I-125 Model 6711 and Pd-103 Model 200 sources, in this report we present an analysis of the dosimetric impact of the 2004 TG-43 dosimetry parameters on the history of dose delivery for these two source models. Our analysis indicates that the currently recommended prescribed dose of 125 Gy for Model 200 Pd-103 implants planned using previously recommended dosimetry parameters [AAPM Pd-103 dose prescription: Williamson et al., Med. Phys. 27, 634-642 (2000)] results in a delivered dose of 120 Gy according to dose calculations based on the 2004 TG-43 update. Further, delivered doses prior to October 1997 varied from 113 to 119 Gy for a prescribed dose of 115 Gy compared to 124 Gy estimated by the AAPM 2000 report. For I-125 implants using Model 6711 seeds, there are no significant changes (less than 2%). Practicing physicians should take these results into account when selecting the clinically appropriate prescribed dose for Pd-103 interstitial implant patients following implementation of the 2004 TG-43 update dose-calculation recommendations. The AAPM recommends that the radiation oncology community review this report and consider whether the currently recommended dose level (125 Gy) needs to be revised. (c) 2005 American Association of Physicists in Medicine.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available