4.7 Review

Critical review of the application of liquid chromatography/mass spectrometry to the determination of pesticide residues in biological samples

Journal

ANALYTICAL AND BIOANALYTICAL CHEMISTRY
Volume 382, Issue 4, Pages 934-946

Publisher

SPRINGER HEIDELBERG
DOI: 10.1007/s00216-005-3185-5

Keywords

pesticide residues; metabolites; liquid chromatography; mass spectrometry; review; human urine; serum; blood

Ask authors/readers for more resources

A critical review is made on the use of hyphenated liquid chromatography/mass spectrometry (LC-MS) for the identification and quantification of pesticides and their metabolites in human biosamples (whole blood, plasma, serum and urine). The first applications of LC-MS in this field began in the early 1990s. Since then, increasing interest has been shown in applying this powerful technique, with most applications dealing with the determination of a variety of chemically diverse metabolites in urine. The use of different LC-MS interfaces and mass spectral detection modes are discussed. Special attention is given to tandem mass spectrometry (MS/MS) due to its inherent advantages of increased sensitivity and selectivity, as well as its advantages for identification and confirmation of analytes in samples. Quantification can be severely affected by matrix effects, the most common being inhibition of the ionisation of analytes in the mass spectrometer, which leads to unacceptable errors if no correction is made. Different approaches can be employed to minimise this undesirable matrix effect, the preferred being the use of labelled internal standards (when available) in isotope dilution methods or the application of an efficient clean-up, performed off-line or automated on-line. Adequate criteria for confirming the identities of residues detected are required in order to avoid false positives. The criterion most commonly used with a triple quadrupole instrument is the monitoring of two MS/MS transitions together with the ion abundance ratio. TOF mass analysers are seldom used in pesticide residue analysis despite their improved resolution and mass accuracy characteristics, which makes them very suitable for confirmation purposes. The main reasons for the relative unpopularity of TOF MS in residue analysis are its limited sensitivity and its high acquisition cost. In this paper, we present a critical assessment on current techniques, trends and future developments, and give illustrative examples to point out the main characteristics of LC-MS for pesticide residue analysis in biological fluids.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available