4.5 Article

Parametric sensitivity study of operating and design variables in wellbore heat exchangers

Journal

GEOTHERMICS
Volume 34, Issue 3, Pages 330-346

Publisher

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.geothermics.2005.02.001

Keywords

wellbore heat exchanger; WBHX; power generation; modeling

Ask authors/readers for more resources

A numerical study was conducted to evaluate the potential for using Wellbore Heat Exchangers (WBHX) to extract heat for use in electricity generation. Variables studied included operational parameters such as wellbore geometries, working fluid properties, circulation rates, and regional properties including basal heat flux and formation rock type. Energy extraction is strongly affected by fluid residence time, heat transfer contact area, and formation thermal properties. Water appears to be the most appropriate working fluid. The effects of tubing properties and casing lengths are of second-order. On the basis of a sensitivity study, a Best Case model was simulated, and results compared against the geothermal fluid requirements of existing power generation plants that use low-temperature geothermal fluids. Even assuming ideal work conversion to electricity, a WBHX cannot supply sufficient energy to generate 200 kWe at the onset of pseudo-steady-state (PSS) conditions. Using realistic conversion efficiencies it is unlikely that the system would be able to generate 50 kWe at the onset of PSS. (c) 2005 CNR. Published by Elsevier Ltd. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.5
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available