4.3 Article

Simultaneous determination of cobalt, copper and zinc by energy dispersive X-ray fluorescence spectrometry after preconcentration on PAR-loaded ion-exchange resin

Journal

ANALYTICAL SCIENCES
Volume 21, Issue 7, Pages 851-854

Publisher

JAPAN SOC ANALYTICAL CHEMISTRY
DOI: 10.2116/analsci.21.851

Keywords

-

Ask authors/readers for more resources

A sensitive method for the preconcentration and determination of trace amounts of Co, Cu and Zn by energy-dispersive X-ray fluorescence spectrometry (EDXRF) has been developed. The method is based on the fact that 4-(2-pyridylazo)-resorcinol (PAR) loaded Dowex anion-exchange resin (PAR-resin) can effectively adsorb Co, Cu and Zn at pH 9.0 to form PAR-metal complexes. The detection limits for Co, Cu and Zn were 1.53, 0.31 and 0.21 ppb, respectively. The precisions for five replicate measurements of the three metals were 3.4, 2.7 and 2.1% RSD, and the calibration curves were linear up to 75 mu g with correlation coefficients of 0.9975, 0.9980 and 0.9985, respectively. The method was successfully applied for the simultaneous determination of Co, Cu and Zn in seawater samples at ppb levels.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.3
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available