Journal
WATER RESEARCH
Volume 39, Issue 13, Pages 2921-2925Publisher
PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.watres.2005.04.067
Keywords
UV inactivation; Escherichia coli; disinfection; microorganism; flashlamp
Ask authors/readers for more resources
Inactivation of Escherichia coli is examined using ultra-violet (UV) radiation from a pulsed xenon flashlamp. The light from the discharge has a broadband emission spectrum extending from the UV to the infrared region with a rich UV content. The flashlamp provides high-energy UV output using a small number of short-duration pulses (30 mu s). The flashlamp is used with a monochromator to investigate the wavelength sensitivity of E. coli to inactivation by the pulsed UV light. Using 8 run wide pulses of UV radiation, the most efficient inactivation is found to occur at around 270 nm and no inactivation is observed above 300 nm. A pyroelectric detector allows the energy dose to be determined at each wavelength, and a peak value for E. coli population reduction of 0.43 log per mJ/cm(2) is measured at 270 nm. The results are compared with the published data available for continuous UV light sources. (c) 2005 Elsevier Ltd. All rights reserved.