4.8 Article

Perfluorinated sulfonamides in indoor and outdoor air and indoor dust: Occurrence, partitioning, and human exposure

Journal

ENVIRONMENTAL SCIENCE & TECHNOLOGY
Volume 39, Issue 17, Pages 6599-6606

Publisher

AMER CHEMICAL SOC
DOI: 10.1021/es048340y

Keywords

-

Ask authors/readers for more resources

Perfluorinated alkyl sulfonamides (PFASs) which are used in a variety of consumer products for surface protection were investigated through a comprehensive survey of indoor air, house dust, and outdoor air in the city of Ottawa, Canada. This study revealed new information regarding the occurrence and indoor air source strength of several PFASs including N-methylperfluorooctane sulfonamido-ethanol (MeFOSE), N-ethylperfluorooctane sulfonamidoethanol (EtFOSE), N-ethylperfluorooctane sulfonamide (EtFOSA), and N-methylperfluorooctane sulfonamidethylacrylate (MeFOSEA). Passive air samplers consisting of polyurethane foam disks were calibrated and used to conduct the indoor and outdoor survey. Indoor air concentrations for MeFOSE and EtFOSE (1490 and 740 pg m(-3), respectively) were about 10-20 times greater than outdoor concentrations, establishing indoor air as an important source to the outside environment. EtFOSA and MeFOSEA concentrations were lower in indoor air (40 and 29 pg m(-3) respectively) and below detection in outdoor air samples. For indoor dust, highest concentrations were recorded for MeFOSE and EtFOSE with geometric mean concentrations of 110 and 120 ng g(-1), while concentrations for EtFOSA and MeFOSEA were below detection and 7.9 ng g(-1) respectively. MeFOSE and EtFOSE concentrations in house dust followed levels in indoor air. However, resolution of the coupled air and dust data (for the same homes) was not successful using existing K-OA-based models for surface air exchange. The partitioning to house dust was greatly underpredicted. The difficulties with existing models may be due to the high activity coefficient of PFASs in octanol and/or a situation where the dust is greatly oversaturated with respect to the air due to components of the dust being contaminated with PFASs. A human exposure assessment based on median air and dust concentrations revealed that human exposure through inhalation (100% absorption assumed) and dust ingestion were similar to 40 and similar to 20 ng d(-1), respectively. However, for children the dust ingestion pathway was dominant and accounted for similar to 44 ng d(-1).

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.8
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available