Ultrafine particles from a vented gas clothes dryer

Journal

ATMOSPHERIC ENVIRONMENT
Volume 39, Issue 32, Pages 5777-5786

Publisher

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.atmosenv.2005.03.050

Keywords

ultrafine particles; clothes dryer; source strength; vented gas appliance

Ask authors/readers for more resources

Ultrafine particles (similar to 10-100nm) were measured continuously for 18 months in an occupied townhouse. A major source was determined to be the gas clothes dryer. Although the dryer was vented to the outdoors it consistently produced an order of magnitude increase in the ultrafine concentrations compared to times with no indoor sources. Short-term peak number concentrations exceeded 100,000cm(-3) on a number of occasions. The source strength was conservatively estimated at about 6 x 10(12) ultrafine particles produced per drying episode. These values are underestimates, since the part of the peak below 9.8nm was not measured. Averaged over 150h of operation, the number concentration showed a major peak at the smallest size measured (9.8nm) and a secondary peak at 30 nm. Loss rates of the ultrafines due to diffusion, deposition, and particle growth (1-2 h(-1)) were high compared to losses due to air exchange (0.1-0.6 h(-1)). Considering the reported health effects of ultrafines, the widespread use of gas dryers, and the substantial amount of time that gas dryers are operated in many homes, it may be desirable to carry out further research to determine if the results reported here for a single dryer in one home are reproducible under different conditions. (c) 2005 Elsevier Ltd. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available