Use of a simple intraoperative hydrostatic pressure test to assess the relationship between mobility of the ventricular stoma and success of third ventriculostomy

Journal

JOURNAL OF NEUROSURGERY
Volume 103, Issue 5, Pages 848-852

Publisher

AMER ASSOC NEUROLOGICAL SURGEONS
DOI: 10.3171/jns.2005.103.5.0848

Keywords

cerebrospinal fluid flow; obstructive hydrocephalus; hydrostatic test; endoscopic third ventriculostomy

Ask authors/readers for more resources

Object. Neuroendoscopists often note pulsatility or flabbiness of the floor of the third ventricle during endoscopic third ventriculostomy (ETV) and believe that either is a good indication of the procedure's success. Note, however, that this belief has never been objectively measured or proven in a prospective study. The authors report on a simple test-the hydrostatic test-to assess the mobility of the floor of the third ventricle and confirm adequate ventricular flow. They also analyzed the relationship between a mobile floor (a positive hydrostatic test) and prospective success of ETV. Methods. During a period of 3 years between July 2001 and July 2004, 30 ETVs for obstructive hydrocephalus were performed in 22 male and eight female patients. Once the stoma had been created, the irrigating Ringer lactate solution was set at a 30-cm height from the external auditory meatus, and the irrigation valve was opened while the other ports on the endoscope were closed. The ventricular floor ballooned downward and stabilized. The irrigation valve was then closed and ports of the endoscope were opened. The magnitude of the upward displacement of the floor was then assessed. Funneling of the stoma was deemed to be a good indicator of floor mobility, adequate flow, and a positive hydrostatic test. All endoscopic procedures were recorded using digital video and recordings were subsequently assessed separately by two blinded experienced neuroendoscopists. Patients underwent prospective clinical follow up during a mean period of 11.2 months (range 1 month-3 years), computerized tomography and/or magnetic resonance imaging studies of the brain, and measurements of cerebrospinal fluid pressure through a ventricular reservoir when present. Failure of ETV was defined as the subsequent need for shunt implantation. The overall success rate of the ETV was 70% and varied from 86.9% in patients with a mobile stoma and a positive hydrostatic test to only 14.2% in patients with a poorly mobile floor and a negative test (p < 0.05). The positive predictive value of the hydrostatic test was 86.9%, negative predictive value 85.7%, sensitivity 95.2%, and specificity 66.6%. Conclusions. The authors concluded that the hydrostatic test is an easy, brief test. A positive test result confirms a mobile ventricular floor and adequate flow through the created ventriculostomy. Mobility of the stoma is an important predictor of ETV success provided that there is no obstruction at the level of the arachnoid granulations or venous outflow. A thin, redundant, mobile third ventricle floor indicates a longstanding pressure differential between the third ventricle and the basal cisterns, which is a crucial factor for ETV success. A positive hydrostatic test may avert the need to insert a ventricular reservoir, thus avoiding associated risks of infection.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available