4.6 Article

Transient-current measurement of the trap charge density at interfaces of a thin-film metal/ferroelectric/metal structure

Journal

APPLIED PHYSICS LETTERS
Volume 87, Issue 19, Pages -

Publisher

AMER INST PHYSICS
DOI: 10.1063/1.2125122

Keywords

-

Ask authors/readers for more resources

A method providing estimation of the trap density at metal/ferroelectric interfaces of a depleted ferroelectric film located between back-to-back Schottky barriers has been developed. The method is based on the recharge of interface traps induced by external bias pulse applied to the metal/ferroelectric/metal structure. It is shown that the transient current under bias pulse can be controlled by the trap recharge on the reverse-biased interface. Using the method, the trap charge density on interfaces of the Pt/PZT/Ir(Ti/SiO2/Si) capacitor was found from transient-current measurements to be two orders of magnitude less than the remnant polarization of PbZrxTi1-xO3 film. (C) 2005 American Institute of Physics.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available