4.8 Article

Piezoelectric immunochip for the detection of dengue fever in viremia phase

Journal

BIOSENSORS & BIOELECTRONICS
Volume 21, Issue 5, Pages 689-695

Publisher

ELSEVIER ADVANCED TECHNOLOGY
DOI: 10.1016/j.bios.2004.12.019

Keywords

dengue virus; clinical detection; quartz crystal microbalance; immunochip; antibody immobilization; monoclonal antibody

Ask authors/readers for more resources

The global prevalence of dengue fever has grown so dramatically in recent years that it is endemic in more than 100 countries and has become a major international public health concern. Moreover, since the flu-like symptoms that accompany dengue fever are atypical and varied, the detection procedures currently used to identify it are cumbersome and time-consuming, making early stage epidemiological control and effective medical treatment of this epidemic almost impossible. In this study, a QCM-based detection system was developed in which two monoclonal antibodies against dengue E and NS-1 protein, respectively, were control orientated immobilized on QCM via protein A to produce an immunochip. Various sample pretreatment procedures were evaluated to ascertain the most suitable combination, and both the simulating samples and the clinical specimen were examined by the immunochip. The results revealed that the cibacron blue 3GA gel-heat denature (CB-HD) method was the most effective sample pretreatment technique. Due to the complex composition of the serum, the immunochip could only effectively quantify dengue viral antigens in a 1/1000 untreated simulated sample. With the help of the CB-HD method, the dilution folds were found to capable of being reduced from 1000 to 100, and the detection limit lowered to 1.727 mu g/ml (E protein) and 0.740 mu g/ml (NS-1 protein) in the original sample. While the cocktail immunochip could not quantify both antigens separately, the higher signal level rendered it a more effective qualification tool for suspect screening. Moreover, the results of the analysis of clinical specimens also proved the ability and future potential of cocktail immunochip in discriminating dengue-positive cases from negative serum specimens in the viremia phase. (c) 2004 Elsevier B.V. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.8
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available