4.7 Article

Analytical considerations of local thermal non-equilibrium conditions for thermal transport in metal foams

Journal

INTERNATIONAL JOURNAL OF THERMAL SCIENCES
Volume 95, Issue -, Pages 73-87

Publisher

ELSEVIER FRANCE-EDITIONS SCIENTIFIQUES MEDICALES ELSEVIER
DOI: 10.1016/j.ijthermalsci.2015.04.007

Keywords

Convection heat transfer; Local thermal non-equilibrium; Metal foam; Thermal performance

Funding

  1. National Natural Science Foundation of China [51406238]
  2. Foundation for Outstanding Young Scientist in Shandong Province [BS2014NJ009]
  3. Fundamental Research Funds for the Central Universities [14CX02106A]
  4. Shanghai Natural Science Foundation [15ZR1423400]

Ask authors/readers for more resources

As a new-type extending surface, metal foam owns great potential in next generation heat transfer technologies. Convective heat transfer performance in metal foams is numerically investigated based on the local thermal equilibrium (LTE) model and the local thermal non-equilibrium (LINE) model. The solid-fluid temperature difference and relative deviation are put forward for quantifying LINE effect. The effects of basic parameters on heat transfer are analysed in depth and the LTNE conditions in metal-foam tube for efficient heat exchangers are summarized. It is indicated that the relative deviation is a more suitable criterion for LTNE effect in metal foam than the solid-fluid temperature difference. The LTNE effect in metal foam is conspicuous for low porosity, large fluid-solid thermal conductivity difference, small duct size, low pore density, and low Reynolds number. Measures lowering proportion of local convective thermal resistance in total thermal resistance, or the ratio of thermal resistance of solid to that of fluid can weaken LINE effect in metal foam. There is no necessary relationship between thermal performance of metal-foam heat exchangers and corresponding LTNE effect. Clarifying LINE conditions in porous foams can lay a foundation for the demarcating criterion of LTE/LTNE models. This can also guide quick and accurate thermal design and verification of metal-foam heat exchangers. (C) 2015 Elsevier Masson SAS. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available