4.7 Article

Transient viremia in HIV-infected patients and use of plasma preparation tubes

Journal

CLINICAL INFECTIOUS DISEASES
Volume 41, Issue 11, Pages 1671-1674

Publisher

UNIV CHICAGO PRESS
DOI: 10.1086/498025

Keywords

-

Funding

  1. NIAID NIH HHS [U01-AI-25914] Funding Source: Medline

Ask authors/readers for more resources

Using plasma preparation tubes for the collection and storage of plasma resulted in factitious, low-level human immunodeficiency virus type 1 (HIV-1) viremia among patients receiving highly active antiretroviral therapy who incurred unnecessary additional clinic visits, laboratory testing, and medication changes. We caution clinicians against the routine use of plasma preparation tubes for collection of blood samples for HIV-1 level 1 quantification.