4.5 Article

Door-opening motion can potentially lead to a transient breakdown in negative-pressure isolation conditions: the importance of vorticity and buoyancy airflows

Journal

JOURNAL OF HOSPITAL INFECTION
Volume 61, Issue 4, Pages 283-286

Publisher

W B SAUNDERS CO LTD
DOI: 10.1016/j.jhin.2005.05.017

Keywords

chickenpox; varicella; nosocomial; aerosol; transmission; negative-pressure isolation room

Ask authors/readers for more resources

A patient with severe chickenpox was admitted to a negative-pressure isolation room. He remained sedated, intubated and mechanically ventilated throughout his admission. He was managed only by nurses immune to chickenpox. A non-immune male nurse occasionally handed equipment through the doorway, without entering the room. Ten days Later, he also developed chickenpox. Sequencing of viruses from the patient and nurse showed the same rare genotype, indicating nosocomial. transmission. An experimental model. demonstrated that, despite negative pressure, opening the door could have resulted in transport of infectious air out of the isolation room, leading to a breakdown in isolation conditions. (C) 2005 The Hospital Infection Society. Published by Elsevier Ltd. All rights reserved.