4.7 Article

Role of imaging in pretreatment evaluation of early invasive cervical cancer: Results of the Intergroup Study American College of Radiology Imaging Network 6651-Gynecologic Oncology Group 183

Journal

JOURNAL OF CLINICAL ONCOLOGY
Volume 23, Issue 36, Pages 9329-9337

Publisher

AMER SOC CLINICAL ONCOLOGY
DOI: 10.1200/JCO.2005.02.0354

Keywords

-

Categories

Funding

  1. NCI NIH HHS [U01 CA080098, U01 CA079778] Funding Source: Medline

Ask authors/readers for more resources

Purpose To compare magnetic resonance imaging (MRI) and computed tomography (CT) with each other and to International Federation of Gynecology and Obstetrics (FIGO) clinical staging in the pretreatment evaluation of early invasive cervical cancer, using surgicopathologic findings as the reference standard. Patients and Methods This prospective multicenter clinical study was conducted by the American College of Radiology Imaging Network and the Gynecologic Oncology Group from March 2000 to November 2002; 25 United States health centers enrolled 208 consecutive patients with biopsy-confirmed cervical cancer of FIGO stage >= IB who were scheduled for surgery based on clinical assessment. Patients underwent FIGO clinical staging, helical CT, and MRI. Surgicopathologic findings constituted the reference standard for statistical analysis. Results Complete data were available for 172 patients; surgicopathologic findings were consistent with FIGO stages IA to IIA in 76% and stage >= IIB in 21 %. For the detection of advanced stage (>= IIB), sensitivity was poor for FIGO clinical staging (29%), CT (42%), and MRI (53%); specificity was 99% for FIGO clinical staging, 82% for CT, and 74% for MRI; and negative predictive value was 84% for FIGO clinical staging, 84% for CT, and 85% for MRI. MRI (area under the receiver operating characteristic curve [AUC], 0.88) was significantly better than CT (AUC, 0.73) for detecting cervical tumors (P = .014). For 85% of patients, FIGO clinical staging forms were submitted after MRI and/or CT was performed. Conclusion CT and MRI performed similarly; both had lower staging accuracy than in prior single-institution studies. Accuracy of FIGO clinical staging was higher than previously reported. The temporal data suggest that FIGO clinical staging was influenced by CT and MRI findings.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available