4.7 Article

Intraductal papillary mucinous neoplasm of pancreas: Multi-detector row CT with 20 curved reformations - Correlation with MRCP

Journal

RADIOLOGY
Volume 238, Issue 2, Pages 560-569

Publisher

RADIOLOGICAL SOC NORTH AMERICA
DOI: 10.1148/radiol.2382041463

Keywords

-

Ask authors/readers for more resources

Purpose: To retrospectively compare accuracy of multi-detector row computed tomography (CT), combined with two-dimensional (2D) curved reformations, and that of magnetic resonance (MR) cholangiopancreatography (MRCP) for characterization of intraductal papillary mucinous neoplasm (IPMN) as malignant, with pathologic examination as reference standard. Materials and Institutional review board approval was obtained, in: formed consent was waived, and study was HIPAA compliant. Twenty-five patients (12 women, 13 men; age range, 44-88 years) with pathologically proved IPMN were examined with dual-phase CT with 1.25-mm-thick sections for pancreatic phase; 2D curved reformations along main pancreatic duct (MPD) were generated. T2-weighted MRCP included thick- and thin-slab single-shot fast spin-echo imaging and transverse fast spin-echo imaging. Two radiologists, blinded. to surgical and pathologic findings, evaluated images for lesion location, septa, mural nodules, communication with MPD, extent and diameter of MPD dilatation, calcifications, and vascular encasement. Malignancy was suspected when one of the following was present: MPD diameter larger than 10 mm, mural nodules, vascular encasement, peripancreatic lymphadenopathy, or metastases. Sensitivity and specificity values for prediction of malignancy were calculated for CT and MRCP. Interobserver variability was determined (K analysis). Results: Excellent correlation between modalities was observed. Cyst communication was seen in 20 and 21 of 24 branch pancreatic duct (BPD) IPMNs with CT and MRCP, respectively. Sensitivity, specificity, and accuracy for detection of malignancy were 70%, 87%, and 76% (CT) and 70%, 92%, and 80% (MRCP), respectively. Interobserver agreement was good to perfect for both readers in all comparisons (overall, kappa = 0.70-1.00). Conclusion: CT combined with 2D curved reformation can provide imaging details of IPMN, including communication of BPD IPMN with MPD, that are at-most equivalent to those provided at MRCP. Presence of mural nodules, dilated MPD (> 10-mm diameter), or thick septa at CT or MRCP may be used as independent predictors of malignancy. (c) RSNA, 2006

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available