Noninvasive Doppler tissue measurement of pulmonary artery compliance in children with pulmonary hypertension

Journal

Publisher

MOSBY-ELSEVIER
DOI: 10.1016/j.echo.2005.11.012

Keywords

-

Funding

  1. NCRR NIH HHS [M01 RR000069] Funding Source: Medline
  2. NHLBI NIH HHS [T32 HL072738, R01 HL067393, HL 067393, HL 072738] Funding Source: Medline

Ask authors/readers for more resources

Background: We have shown previously that input impedance of the pulmonary vasculature provides a comprehensive characterization of right ventricular afterload by including compliance. However, impedance-based compliance assessment requires invasive measurements. Here, we develop and validate a noninvasive method to measure pulmonary artery (PA) compliance using ultrasound color M-mode (CMM) Doppler tissue imaging (DTI). Methods: Dynamic compliance (C-dyn) of the PA was obtained from CMM DTI and continuous wave Doppler measurement of the tricuspid regurgitant velocity. C-dyn was calculated as: [(D-s-D-d)/(D(d)xP(s))]x 10(4) where D-s = systolic diameter, D-d = diastolic diameter, and P-s = systolic pressure. The method was validated both in vitro and in 13 patients in the catheterization laboratory, and then tested on 27 pediatric patients with pulmonary hypertension, with comparison with 10 age-matched control subjects C-dyn was also measured in an additional 13 patients undergoing reactivity studies. Results: Instantaneous diameter measured using CMM DTI agreed well with intravascular ultrasound measurements in the in vitro models. Clinically, C-dyn. calculated by CMM DTI agreed with C-dyn calculated using invasive techniques (23.4 +/- 16.8 vs 29.1 +/- 20.6%/100 mm Hg; P = not significant). Patients with pulmonary hypertension had significantly lower peak wall velocity values and lower C-dyn, values than control subjects (P < .01). C-dyn values followed an exponentially decaying relationship with PA pressure, indicating the nonlinear stress-strain behavior of these arteries. Reactivity in C-dyn agreed with reactivity measured using impedance techniques. Conclusion: The C-dyn method provides a noninvasive means of assessing PA compliance and should be useful as an additional measure of vascular reactivity subsequent to pulmonary vascular resistance in patients with pulmonary hypertension.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.5
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available