4.5 Article

Urinalysis of 4-hydroxynonenal, a marker of oxidative stress, using stir bar sorptive extraction-thermal desorption-gas chromatography/mass spectrometry

Publisher

ELSEVIER
DOI: 10.1016/j.jchromb.2006.02.038

Keywords

stir bar sorptive extraction; gas chromatography-mass spectrometry; 4-hydroxynonenal; oxidative stress; urine samples

Ask authors/readers for more resources

A simple and fast method for the measurement of 4-hydroxynonenal (4HNE), a highly toxic end-product of lipid peroxidation, in urine samples is described. The method combines stir bar sorptive extraction (SBSE) with two derivatization steps, followed by thermal desorption and GC/MS. 4HNE is derivatized in situ with O-(2,3,4,5,6-pentafluorobenzyl) hydroxylamine and the oxime is extracted from the aqueous phase with SBSE. The 4HNE-oxime is further acylated by headspace derivatization prior to thermal desorption. Derivatization reactions and extraction were optimized in terms of reagent quantities, temperature and time. The method is linear over a concentration range of 0.5-5 no mL(-1) with a correlation coefficient of 0.997. The limit of detection and limit of quantitation are 22 and 75 pg mL(-1) urine, respectively. The high sensitivity of the method allows the measurement of physiological concentrations of 4HNE in urine samples. (c) 2006 Elsevier B.V. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.5
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available