4.7 Article

Effects of time, dose, and inversion time for acute myocardial infarct size measurements based on magnetic resonance imaging-delayed contrast enhancement

Journal

JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY
Volume 47, Issue 10, Pages 2027-2033

Publisher

ELSEVIER SCIENCE INC
DOI: 10.1016/j.jacc.2006.01.059

Keywords

-

Funding

  1. NHLBI NIH HHS [R01-HL63268, R01-HL64726, K02-HL04394] Funding Source: Medline

Ask authors/readers for more resources

OBJECTIVES This study sought to investigate the influence of time, dose, and inversion time (TI) and their interactions on myocardial infarct size measurements to establish the foundation for a standardized protocol for multicenter trials. BACKGROUND There is growing interest in using magnetic resonance imaging (MRI) infarct size measurements as an end point in clinical trials. However, no standardized protocol exists, and there are limited data concerning the effects of time, contrast agent dose, and TI. METHODS First, we determined the influence of postcontrast imaging time (5 to 40 min), contrast agent dose (0.1 vs. 0.2 mmol/kg), TI, and their interactions in an animal model (n = 14). Second, we tested whether the findings of the animal study apply to patients and are generalizable. Therefore, we retested the diagnostic window in a multicenter study. A total of 48 patients with first acute myocardial infarction (AMI) from three centers were imaged twice (5 and 30 min) after injection of 0.15 mmol/kg gadolinium diethylenetriamine-pentaacetate using an adjusted TI. RESULTS The animal study showed that the infarct size is independent of time and dose (p = 0.9 and p = 0.16, respectively) using an adjusted TI. Using a fixed TI, however, infarct size is a function of time and dose (p = 0.0001 and p = 0.01, respectively). The multicenter study showed that MRI 1 (16.9 +/- 12% of left ventricle) was not statistically different from MRI 2 (16.4 +/- 12% of left ventricle, p = NS) with no difference between sites (p = NS). CONCLUSIONS The AMI size can be measured with MRI using a contrast dose between 0.1 and 0.2 mmol/kg and a time window of 5 to 30 min after contrast administration, provided that the TI is adjusted. (J Am Coll Cardiol 2006;47:2027-33) (c) 2006 by the American College of Cardiology Foundation.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available