4.7 Article

Metal ion release from nitrogen ion implanted CoCrMo orthopedic implant material

Journal

SURFACE & COATINGS TECHNOLOGY
Volume 200, Issue 20-21, Pages 5687-5697

Publisher

ELSEVIER SCIENCE SA
DOI: 10.1016/j.surfcoat.2005.08.113

Keywords

cobalt-chromium-molybdenum alloy; metal ion release; nitrogen ion implantation; simulated body fluid; X-ray diffraction; atomic absorption spectroscopy; atomic force microscopy

Ask authors/readers for more resources

CoCrMo alloys are used as orthopedic implant materials because of their excellent mechanical and corrosion properties. However, when placed in vivo, these alloys release Co, Cr, Mo ions to host tissues, which may give rise to significant health concerns over time. Nitrogen ion implantation can be used to form protective layers on the surface of CoCrMo orthopedic alloys by modifying the near surface layers of these materials. In this study, medical grade CoCrMo alloy (ISO 5832-12) was ion implanted with 60 keV nitrogen ions to a high dose of 1.9 x 10(18) ions/cm(2) at substrate temperatures of 100, 200 and 400 degrees C. The N implanted layer microstructures, implanted layer phases, and thicknesses were studied by a combination of Bragg-Brentano (theta/2 theta) and grazing incidence (Seeman-Bohlin) X-ray diffraction (XRD and GIXPD) and cross-sectional scanning electron microscopy (SEM). Atomic force microscopy (AFM) was used for roughness analysis of N implanted as well as as-polished surfaces. Static immersion tests were performed to investigate metal ion release into simulated body fluid (SBF) by electrothermal atomic absorption spectrometry (ETAAS) and inductively Coupled plasma optical emission spectrometry (ICP-OES). XRD and SEM analyses indicated that the N implanted layers were similar to 150-450 nm thick and composed of the (Co,Cr,Mo)(2+x)N nitride phase and a high N concentration Co-based FCC phase, gamma(N) depending on the substrate temperature. ETAAS analysis results showed that in vitro exposure of the N implanted surfaces resulted in higher levels of cobalt ion release into the simulated body fluid compared to the untreated, polished alloy. The higher Co release from the N implanted specimens is attributed to the nature of the implanted layer phases as well as to the rougher surfaces associated with the N implanted specimens compared to the relatively smooth surface of the untreated material. SEM analysis of N implanted and untreated specimens after immersion tests clearly indicated calcium phosphate formation on the as-polished CoCrMo alloy, indicating a degree of bioactivity of the untreated metal surface which is absent in the N implanted specimens. (c) 2005 Elsevier B.V. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available