4.2 Article

Clinical outcomes of low-risk patients undergoing beating-heart surgery with or without pulmonary artery catheterization

Journal

JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA
Volume 20, Issue 3, Pages 300-306

Publisher

W B SAUNDERS CO-ELSEVIER INC
DOI: 10.1053/j.jvca.2006.01.017

Keywords

pulmonary artery catheterization; beating-heart surgery; morbidity; mortality; anesthesia techniques; OPCAB

Ask authors/readers for more resources

Objective: For patients who undergo off-pump coronary artery bypass (OPCAB) surgery, pulmonary artery catheterization (PAC) has been proposed as a useful intraoperative monitoring tool. This study was designed to determine if the choice of PAC versus central venous pressure monitoring (CVP) had any effect on outcome after OPCAB. This study compared these 2 methods of hemodynamic monitoring in low-risk patients undergoing beating-heart surgery via a median sternotomy and evaluated their effect on morbidity and in-hospital mortality. Design: Retrospective database and medical record review. Setting: Tertiary care teaching hospital. Participants: Low-risk patients who had coronary revascularization via a median sternotomy on the beating heart. Interventions: None. Measurements and Main Results: A population of 2,414 low-risk patients who had beating-heart coronary revascularization between January 2000 and December 2003 was reviewed. Most patients (1,671 or 69.2%) received a PAC, whereas 743 (30.8%) had CVP monitoring. Risk-adjusted logistic regression analyses were performed to investigate the effect of each technique on clinical outcomes. The groups were comparable in both baseline characteristics and Parsonett's mortality risk (1.5 +/- 0.9, p = 0.58). Univariate analysis failed to show a difference in operative mortality (p = 0.76), on-pump conversion rate for completion of aortocoronary bypasses (p = 0.82), postoperative low cardiac output (p = 0.10), or prolonged inotropic agent use (p = 0.22). Similarly, in the multivariate analysis, both groups had a similar rate of conversion to an on-pump procedure for completion of coronary artery grafting (p = 0.91), intraoperative intra-aortic balloon pump use (p = 0.69), low cardiac output state (p = 0.16), or in-hospital mortality (p = 0.51). Conclusions: This sing le-institution, retrospective study suggests that in low-risk patients undergoing beating-heart surgery, CVP monitoring may be sufficient. (C) 2006 Elsevier Inc. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.2
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available