4.6 Article

Transepidermal water loss reflects permeability barrier status:: validation in human and rodent in vivo and ex vivo models

Journal

EXPERIMENTAL DERMATOLOGY
Volume 15, Issue 7, Pages 483-492

Publisher

WILEY
DOI: 10.1111/j.1600-0625.2006.00437.x

Keywords

barrier function; epidermal permeability barrier; surface temperature; transepidermal water loss

Categories

Funding

  1. NCRR NIH HHS [RR00173] Funding Source: Medline
  2. NIAMS NIH HHS [AR 39448, AR 050629] Funding Source: Medline
  3. NICHD NIH HHS [HD29706] Funding Source: Medline

Ask authors/readers for more resources

Permeability barrier function is measured with instruments that assess transepidermal water loss (TEWL), either with closed- or open-loop systems. Yet, the validity of TEWL as a measure of barrier status has been questioned recently. Hence, we tested the validity of this measure by comparing TEWL across a wide range of perturbations, with a variety of methods, and in a variety of models. TEWL rates with two closed-chamber systems (VapoMeter and H4300) and one closed-loop system (MEECO) under different experimental in vivo conditions were compared with data from four open-loop instruments, i.e. TM 210, TM 300, DermaLab and EP 1. The instruments were compared in vivo both in humans and hairless mice skin subjected to different degrees of acute barrier disruption. The values obtained with bioengineering systems were correlated with absolute water loss rates, determined gravimetrically. Measurements with both closed and open systems correlated not only with each other, but each method detected different degrees of barrier dysfunction. Although all instruments differentiated among gradations in TEWL in the mid-range of barrier disruption in vivo, differences in very low and very high levels of disruption were less accurately measured with the H4300 and DermaLab systems. Nevertheless, a high Pearson correlation coefficient (r) was calculated for data from all instruments vs. gravimetrically assessed TEWL. Together, these results verify the utility of TEWL as a measure of permeability barrier status. Moreover, all tested instruments are reliable tools for the assessment of variations in permeability barrier function.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available