4.7 Article

Real-Time Use of Artificial Intelligence in Identification of Diminutive Polyps During Colonoscopy A Prospective Study

Journal

ANNALS OF INTERNAL MEDICINE
Volume 169, Issue 6, Pages 357-+

Publisher

AMER COLL PHYSICIANS
DOI: 10.7326/M18-0249

Keywords

-

Funding

  1. Japan Society for the Promotion of Science [17H05305]

Ask authors/readers for more resources

Background: Computer-aided diagnosis (CAD) for colonoscopy may help endoscopists distinguish neoplastic polyps (adenomas) requiring resection from nonneoplastic polyps not requiring resection, potentially reducing cost. Objective: To evaluate the performance of real-time CAD with endocytoscopes (x520 ultramagnifying colonoscopes providing microvascular and cellular visualization of colorectal polyps after application of the narrow-band imaging [NBI] and methylene blue staining modes, respectively). Design: Single-group, open-label, prospective study. (UMIN [University hospital Medical Information Network] Clinical Trial Registry: UMIN000027360). Setting: University hospital. Participants: 791 consecutive patients undergoing colonoscopy and 23 endoscopists. Intervention: Real-time use of CAD during colonoscopy. Measurements: CAD-predicted pathology (neoplastic or nonneoplastic) of detected diminutive polyps (5 mm) on the basis of real-time outputs compared with pathologic diagnosis of the resected specimen (gold standard). The primary end point was whether CAD with the stained mode produced a negative predictive value (NPV) of 90% or greater for identifying diminutive rectosigmoid adenomas, the threshold required to diagnose-and-leave nonneoplastic polyps. Best- and worst-case scenarios assumed that polyps lacking either CAD diagnosis or pathology were true- or false-positive or true- or false-negative, respectively. Results: Overall, 466 diminutive (including 250 rectosigmoid) polyps from 325 patients were assessed by CAD, with a pathologic prediction rate of 98.1% (457 of 466). The NPVs of CAD for diminutive rectosigmoid adenomas were 96.4% (95% CI, 91.8% to 98.8%) (best-case scenario) and 93.7% (CI, 88.3% to 97.1%) (worst-case scenario) with stained mode and 96.5% (CI, 92.1% to 98.9%) (best-case scenario) and 95.2% (CI, 90.3% to 98.0%) (worst-case scenario) with NBI. Limitation: Two thirds of the colonoscopies were conducted by experts who had each experienced more than 200 endocytoscopies; 186 polyps not assessed by CAD were excluded. Conclusion: Real-time CAD can achieve the performance level required for a diagnose-and-leave strategy for diminutive, nonneoplastic rectosigmoid polyps.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available