4.6 Article

Microfluidic bypass for efficient passive regulation of droplet traffic at a junction

Journal

APPLIED PHYSICS LETTERS
Volume 89, Issue 3, Pages -

Publisher

AMER INST PHYSICS
DOI: 10.1063/1.2221929

Keywords

-

Ask authors/readers for more resources

We propose a simple design for microfabricated junctions that allows an equal and regular distribution of droplets between the two outlets of a T junction. It relies on establishing a connection between the two outlets shortly after the junction to provide short-time memory to the device and induce perfect alternation in the choice of the outlet. We experimentally demonstrate the benefits of this simple passive device by a direct comparison to junctions without bypasses. (c) 2006 American Institute of Physics.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available