Rapid semi-continuous calibration and field test of membrane-enclosed silicone collector as passive water sampler

Journal

JOURNAL OF CHROMATOGRAPHY A
Volume 1124, Issue 1-2, Pages 187-195

Publisher

ELSEVIER SCIENCE BV
DOI: 10.1016/j.chroma.2006.06.094

Keywords

membrane-enclosed silicone collector (MESCO); silicone rod; chlorinated hydrocarbons; polycyclic aromatic hydrocarbons; water monitoring; passive sampling

Ask authors/readers for more resources

The new membrane-enclosed silicone collector (MESCO) was, in two different configurations with respect to the thickness of low-density polyethylene membrane used, subject to serial batch extraction tests to obtain (preliminary) sampling rates for estimating water concentrations of selected chlorinated organic compounds and polycyclic aromatic hydrocarbons. This rapid calibration procedure is simple to implement compared to experiments in a flow-through apparatus and yielded reasonable sampling rates in the range of 50 mu L-2 mL per hour for the compounds tested. The new MESCO formats were also exposed for 28 days in the polluted creek to test their field performance. For priority contaminants of special interest, alpha-hexachlorocyclohexane and hexachlorobenzene, the time-weighted average concentrations derived from the freshly calibrated sampling devices agree well with those obtained by conventional water analysis of spot samples. (c) 2006 Published by Elsevier B.V.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available